TM 9-2320-366-10-1
Table 2-5. Preventive Maintenance Checks and Services (M1089) (Cont)
Location
Item
No.
Interval
Item to
Check/
Service
Crewmember
Procedure
Not Fully
Mission Capable
If:
13
During
MHC
Operation
(Cont)
p. Move BOOM lever in
UP position (para 2-
50g) to increase angle.
q. Move BOOM lever in
DOWN position (para 2-
50g) to decrease boom
angle.
p. Boom angle
does not
increase.
q. Boom angle
does not
decrease.
WARNING
Wear heavy leather-palmed work gloves when handling cable.
Cables can become frayed or contain broken wires. Never let
moving cable slide through hands, even when wearing gloves.
Failure to comply may result in injury to personnel.
r. Check that part of cable
which is visible for
kinks, frays, or breaks.
r. Kinks, frays,
or breaks in
cable are
found.
2-173