TM 9-2320-366-10-1
Table 2-5. Preventive Maintenance Checks and Services (M1089) (Cont)
Location
Item
No.
Interval
Item to
Check/
Service
Crewmember
Procedure
Not Fully
Mission Capable
If:
13
During
MHC
Operation
(Cont)
s. Check that pulley at
end of boom is
mounted securely, turns
smoothly, and is not
damaged.
s. Pulley is
damaged, not
mounted
securely, or
does not turn
smoothly.
t.
Check that hoist is
mounted securely and
is not damaged.
u. Move HOIST lever in
UP position (para 2-
50g) to reel in cable.
t.
Hoist is not
mounted
securely or is
damaged.
u. Hoist does not
reel in cable.
14
During
MHC
Remote
Controls
a. Check remote control
cable for cracked
insulation and damage
to plugs on cable ends.
b. Check REMOTE
CONTROL UNIT for
broken controls or other
obvious damage.
a. Insulation is
cracked and
bare wire is
exposed or
cable plug is
damaged.
2-174
Change 1