TM 9-2320-366-10-1
2-27. VEHICLE OPERATION (CONT)
CAUTION
Do not press ether start switch unless engine is cranking. Failure to
comply may result in damage to engine.
Do not use ether after the engine has reached idle speed (750 rpm) and
is no longer in danger of stalling. Failure to comply may result in damage
to engine.
NOTE
Continue to inject ether if engine has started but will not run without ether.
If outside air temperature is 32F to -25F (0C to -32C) perform steps (6)
and (7).
(7) Press and hold ether start switch (8) for approximately three seconds and release for
two seconds.
(8) Repeat step (7) until engine has started, engine speed has increased over cranking
speed, and engine maintains speed.
2-216